Skip to Content

0745A Loadcell

Smart Digital Load Cells for Vehicle Scales – No Junction Box Needed Designed for a wide range of industrial applications, the 0745A Loadcell delivers high accuracy and durability, even in the harshest environments.

Unmatched Accuracy

Benefit from exceptional precision with advanced technology that compensates for temperature changes, mechanical stresses, and signal interference, ensuring reliable and consistent measurements.

Built for Durability

The 0745A Loadcell is engineered to withstand tough industrial conditions, with a robust construction that ensures long-lasting performance in demanding environments.

Superior Performance

Achieve superior weighing results with cutting-edge technology that enhances performance and surpasses traditional analog systems, providing faster and more accurate readings.

Specifications

FeatureDetails
Model
0745A
Type
Beam Load Cell
Rated Capacities
110 kg (250 lb), 220 kg (500 lb), 550 kg (1250 lb), 1100 kg (2500 lb), 2200 kg (5000 lb), 4400 kg (10000 lb)
Rated Output
110 kg–1100 kg: 1.940 ± 0.1% mV/V
2200 kg–4400 kg: 2.000 ± 0.1% mV/V
Zero Load Output
≤ 1.0 %R.C.
Combined Error
C3: ≤ 0.018 %R.C.
C6: ≤ 0.012 %R.C.
Repeatability Error
C3: ≤ 0.01 %A.L.
C6: ≤ 0.005 %A.L.
Creep (30 min)
C3: ≤ 0.017 %A.L.
C6: ≤ 0.008 %A.L.
Temperature Effect on Zero Load Output
C3: ≤ 0.0013 %R.C./°C (0.0007 %R.C./°F)
C6: ≤ 0.0013 %R.C./°C (0.0007 %R.C./°F)
Temperature Effect on Sensitivity
C3: ≤ 0.001 %A.L./°C (0.0006 %A.L./°F)
C6: ≤ 0.0005 %A.L./°C (0.0003 %A.L./°F)
Temperature Range
Compensated: -10 °C to +40 °C (+14 °F to +104 °F)
Operating: -40 °C to +65 °C (-40 °F to +150 °F)
Safe Storage: -40 °C to +80 °C (-40 °F to +176 °F)
OIML Approval
Class C3 / C6
NTEP Approval
Class III M / III L M
Hazardous Area Approvals
ATEX / IECEx Zone 1/2 and 21/22, FM Class I, II, III Div 1&2 (USA & Canada)
Excitation Voltage
Recommended: C3: 5–15 V AC/DC; C6: 5–10 V AC/DC
Maximum: 15 V AC/DC
Terminal Resistance
Excitation: 384 ± 10 Ω
Output: 350 ± 2 Ω
Insulation Resistance
> 5000 MΩ @ 50 V DC
Materials
Spring Element: Stainless steel
Enclosure: 304 Stainless steel
Cable Entry Fitting: 304 Stainless steel
Protection Rating
IP68, IP69K, NEMA 6/6P
Overload Limits
Safe Load Limit: 150 %R.C.
Ultimate Load Limit: 300 %R.C.
Safe Side Load: 100 %R.C.
Safe Dynamic Load: 70 %R.C.
Cable Specifications
Material Options: Polyurethane (PU) or FEP
Diameter: PU: 5.2 mm (0.2 in); FEP: 5.3 mm (0.21 in)
Standard Lengths: PU: 2 m, 3 m, 5 m, 10 m (6.6 ft, 9.8 ft, 16.4 ft, 32.8 ft)
FEP: 3 m, 5 m, 10 m (9.8 ft, 16.4 ft, 32.8 ft)
₹ 0.00 ₹ 0.00

Useful Related Links

Weigh Module Systems Engineering Handbook

With more than 150 fact-filled pages, the Handbook helps you select and apply weigh modules to create high-performance weighing or inventory control systems. Explore critical guidelines for professionals in engineering, operations, or integration.

44098237_B_MAR_HB_System_Handbook_WeighModule_EN (3).pdf

Weigh Module Buying Guide

The weigh module buying guide leads engineers through 8 steps to make the right weigh module selection for any application. Find information about load cell input voltage, load cell wiring, bidirectional load cell solutions – and more!

weighing_module_buying_module.pdf

Industrial Weighing Catalog

Our Industrial Weighing Catalog is updated with our latest solutions to help you optimize your processes. Download the catalog and discover how our innovative weighing, dimensioning, and software solutions can enhance your production!
Industrial_Weighing_Catalog_2024_India-EN_compressed.pdf

Useful Video Links

Tank Scale Installation with PinMount™ and PowerMount™ Weigh Modules

SWC515-A PinMount™ and SWC615-A PowerMount™ weigh modules.

The PinMount and PowerMount weigh modules ensure proper scale system installation, right from the start. Service features, including SafeLock™, provide easy and trouble-free setup. Welding or bolting the weigh modules to the tank scale structure is possible, and the load cell is protected during the installation. Installing or changing the load cell can be done any time, and a later upgrade to METTLER TOLEDO's POWERCELL technology is also possible.

How to Install Weigh Modules Quickly

The video deals with the key values of modern #weigh modules which is true for SWB505 MultiMount™, SWB605 PowerMount™ and SWC515 PinMount™.
SWB505 MultiMount™ weigh modules let you add weighing capabilities to your process by converting a tank, conveyor or other structure into a scale. They are designed for static and dynamic applications with no compromise on safety – all safety features are standard, including FM, IECEx and ATEX Approvals. The proven rocker pin design and metrologically approved load cells provide the highest level of weighing accuracy. SWB505 MultiMount™ features including SafeLock™ ensure easy, safe and trouble-free installation and operation right from the start.

Industrial Weighing Catalog

Our Industrial Weighing Catalog is updated with our latest solutions to help you optimize your processes. Download the catalog and discover how our innovative weighing, dimensioning, and software solutions can enhance your production!
Industrial_Weighing_Catalog_2024_India-EN_compressed.pdf


Contact Us

We'd love to hear from you! If you have any questions, feedback, or need assistance, please feel free to reach out to us using the contact details provided. Our team is here to help and will respond as soon as possible. Thank you for getting in touch!

Email

       mail@attackticlabs.in

Phone

       +91 9289438897

Office

​Sx01, 6th Floor, URB Tech NPX, Sector 153, ​Noida, PIN 201310